LG
LG THERMA V Hydrosplit IWT
LG THERMA V (Hydrosplit) air-to-water heat pump, 12kW, single-phase. Refrigerant R32.
Choose Capacity
Download Technical Datasheet (PDF)Technical Specifications
CategoryHeat Pumps & Fan Coils
BrandLG
Indoor Unit Weight (kg)130.0
Outdoor Unit Weight (kg)91.7
Capacity (kW)12 kW
Domestic Hot Water Energy ClassA+
Heat Output (kW)12.00 kW (A7/W35) / 11.00 kW (A7/W55) / 11.00 kW (A2/W35)
Outdoor Temperature Operating Range (Heating)-25°C to 35°C
Outdoor Unit Dimensions (HxWxD mm)1380 x 950 x 330
Maximum Supply Water Temperature (°C)65 °C
Outdoor Unit Sound Pressure Level (dBA)39 (at 5 m)
Supply Water Temperature Range (Cooling)5°C to 27°C (16°C to 27°C when no fan coil is used)
Indoor Unit Sound Power Level (dBA)43
Seasonal Heating Efficiency ηs (55°C water)137 %
Outdoor Unit Sound Pressure Level - Low Noise (dBA)38 (at 5 m)
Heating Energy Class (55°C)A++
PhaseSingle-phase
Domestic Hot Water Seasonal Efficiency ηwh (profile L)120 %
Heating COP5.04 (A7/W35) / 2.90 (A7/W55) / 3.65 (A2/W35)
Heating SCOP (35°C water)4.60
Outdoor Unit Sound Power Level LW(A) (dB)61
Heating Energy Class (35°C)A+++
Domestic Hot Water COP (average climate)2.74
Indoor Unit Dimensions (HxWxD mm)1812 x 601 x 685
Domestic Hot Water Tank (Volume / Material)200 l / Enamelled steel
Refrigerant - DetailsR32, GWP 675, 2.1 kg
Cooling EER4.75 (A35/W18) / 2.70 (A35/W7)
Electrical Characteristics1~/50Hz/220-240V
Water Pipe ConnectionsMale PT 1" (ISO 7-1), inlet/outlet
Measurement ConditionsA: outdoor air temperature, W: leaving water temperature (LWT)
Water Temperature Range (Domestic Hot Water)15°C to 80°C (above 55°C only with booster heater operation)
Domestic Hot Water Load ProfileL
Supply Water Temperature Range (Heating)15°C to 65°C
Outdoor Temperature Operating Range (Cooling)5°C to 48°C
Cooling Output (kW)12.00 kW (A35/W18) / 12.00 kW (A35/W7)
Outdoor UnitHU121MRB U30
Indoor Unit Operating Current (A)8.7 / 17.4 (Case 1 / Case 2)
RefrigerantR32
Outdoor Unit Sound Power Level - Low Noise (dB)60
Seasonal Heating Efficiency ηs (35°C water)181 %
Indoor UnitHN1616Y NB1
Recommended Circuit Breaker (A)40
Booster Electric Heater (kW)2.0 / 2.0 + 2.0 (Case 1 / Case 2)
Indoor Unit Sound Pressure Level (dBA)35 (at 1 m)
Heating SCOP (55°C water)3.50