Olympus
200‐1‐S230
TANK Dimensions (mm): 530 x 1215 Capacity (l) : 200 COLLECTOR Dimensions (mm): 1960 x 960 x 81 Number of Collectors: 1 Collector Area (m²): 2.28 Maximum Operating Pressure (bar) : 22.5
Download Catalogue (PDF)Technical Specifications
CategorySolar Water Heaters - Boilers
BrandOlympus
Collector Area (m²)2,28
Collector Circuit Test Pressure (bar)22,5
Absorber Material0.50 mm selective blue aluminium, laser-welded to copper tubes
CertificationSolar Keymark, EN 12976-1/2, EN 12975-2 (collector)
Tank InsulationCFC-free polyurethane 40-50 mm (40 kg/m³)
Number of Collectors1
Anodic ProtectionMagnesium rod
Maximum Collector Circuit Temperature (°C)150
Tank Dimensions (mm)530 x 1215
Collector Insulation40 mm stone wool (50 kg/m³) at the back and 20 mm glass wool (30 kg/m³) at the sides
Tank MaterialUSD 37.2 steel with double enamel (glass) coating, fired at 860°C
Emissivity (ε)5% (±0,02)
Collector Cover3.2 mm low-iron prismatic solar glass, 90.5% transmittance
Maximum Tank Operating Pressure (bar)10
Collector Weight (kg)35,5
Tank Capacity200 Lt
Collector SealingAcrylic foam, structural silicone
System TypeClosed-circuit thermosiphon solar system
Collector FrameAluminium profile, without screws or nails
Backup Electric HeaterYes
Maximum Collector Circuit Operating Pressure (bar)15
Empty Tank Weight (kg)61
Heat ExchangerInternal heat exchanger of EN 10219 steel, 3.0 mm thick
Water Temperature Retentionup to 48 hours
Maximum Operating Pressure (bar)22,5
Collector Dimensions (mm)1960 x 960 x 81
Tank Outer CoverGalvanised sheet steel with electrostatic paint, RAL 9006
Maximum Collector Operating Temperature (°C)150
Collector Efficiency (η0)0,763
Absorptance (α)95% (±0,02)