Actionair
A60 MARINE FIRE DAMPER
The A60 MARINE FIRE DAMPER is a marine fire damper for ship air conditioning and ventilation systems, in dry filtered air. It is tested and approved for installation in class A-0, A-15, A-30 and A-60 divisions, i.e. bulkheads and decks, with suitable insulation. It holds DNV, Lloyd’s Register and ABS type approvals and is also available in ATEX versions.
Download Technical Datasheet (PDF)Technical Specifications
CategoryPassive Fire Protection
BrandActionair
Closed Blade TightnessClass 3 with blade seals (EN 1751:2014)
ApprovalsMED 2014/90/EU, Lloyd's Register, DNV-GL, ABS (2005 Steel Vessel Rules 1-1-4/7.7), USCG (164.139), Transport Canada, Sira (Ex) category 2
Version 1Blades of ferritic stainless steel 430, casing of galvanised steel
Electric Actuator (standard)Direct-coupled spring return, ETR 72°C, release time 20 s, reset 60 s, IP54, 24V AC/DC, 230V AC or 120V AC
ATEX versionsAvailable for explosive atmospheres
Maximum Air Velocity15 m/s
Pneumatic Actuator (ATEX)Dry filtered instrument air 5–8 bar, reset/release time 3 s, Pneumatic Thermal Release with 74°C fusible link
Environmental TestsCorrosion BS EN 60068-2-52 (severity 2), vibration BS EN 60068-2-6 (5–350 Hz @ 2g)
Mounting PositionVertical and horizontal, airflow in any direction; normally open, fail-safe closed
ABS approvalProduct Design Assessment (American Bureau of Shipping)
DNV approvalType Approval
Size Range100x100 mm to 1000x1000 mm (width/height in 1 mm steps), multiple units for larger openings (up to 1000x2080 mm)
Lloyd’s Register approvalPer the IMO Fire Test Procedures Code, Annex 1, Part 3, for classes A-0, A-15, A-30 and A-60
CertificatesCertificate of Fire Approval
BladesAerodynamic double-skin, 75 mm pitch, 0.5 mm thick
Schischek actuatorUniversal voltage 24–230V AC/DC, reset time 3–15–30–60–120 s (adjustable), release 3–10 s, ExPro-TT 72°C, operation down to -40°C with built-in heater
Splitter classesA-0, A-15, A-30 and A-60 (with suitable insulation)
Casing TightnessClass C (EN 1751:2014), Eurovent 2/2 classes A and B, HVCA DW144 classes A, B, C
Version 2Blades, casing and drive mechanism of austenitic stainless steel 316
ApplicationShip air conditioning and ventilation systems, dry filtered air
Maximum System Pressure1500 Pa
TypeMarine fire damper for bulkheads and decks
Test GlowMarine fire resistance test IMO A754(18) / FTP Code 2010 Annex 1 Part 3, 60-minute duration
Casing Thickness1.2 mm galvanised or 316 stainless steel (1.4401), optionally 2 mm and 3 mm
Quality System CertificationISO 9001, ISO 14001